we could supply high quality solutions, aggressive value and greatest customer support. Our destination is “You come here with difficulty and we provide you with a smile to take away” for factory Outlets for Electric Heating Plate For University Laboratory, We are seeking forward to even larger cooperation with overseas clients depending on mutual gains. Please truly feel free to get in touch with us for more depth!
we could supply high quality solutions, aggressive value and greatest customer support. Our destination is “You come here with difficulty and we provide you with a smile to take away” for Electric Heating Plate For Laboratory University Inspection Department, Electric Heating Plate For University Laboratory, We adopt advanced production equipment and technology, and perfect testing equipment and methods to ensure our product quality. With our high-level talents, scientific management, excellent teams, and attentive service, our products are favored by domestic and foreign customers. With your support, we will build a better tomorrow!
Chemical composition:

Main and minor components Min.content(%) ASTM B386 (361)
Mo Balance balance
Ti 0.40-0.55% 0.40-0.55%
Zr 0.06-0.12% 0.06-0.12%
Impurities Max.values (μg/g) Max.values (μg/g)
Al 10 -
Cu 20 -
Cr 20 -
Fe 20 100
K 20 -
Ni 10 50
Si 20 100
W 300 -
C 100-400 100-400-
H 10 -
N 10 20
O 500 300
Cd 5 -
Hg 1 -
Pb 5 -

Dimensions and tolerances:

Cold rolled sheets
Thickness(mm) Thickness tolerace(±mm) Maximal width(mm) Width tolerace(±mm)
0.30-0.50 0.028 300 1.0
Hot rolled sheets
Thickness(mm) Thickness tolerace(±mm) Maximal width(mm) Width tolerace(±mm)
0.50-0.60 0.06 850 1.6
0.60-1.00 0.08 850 1.6
1.00-1.50 0.13 850 2.0
1.50-2.00 0.15 850 2.0
2.00-3.60 0.18 850 2.0
3.60-50.0 5% 1000 2.0

Length tolerance:
The length tolerance for all dimension is maximal +5/-0 mm.
Flatness: max. 4 % (measuring procedure on the basis of ASTM B 386)
Density: ≥ 10.1 g/cm³
Vickers Hardness: 220-320 HV
Tensile Test:

Thickness (mm) Tensile StrengthMin. (MPa) 0.2% Yield strengtMin.(MPa) ElongationMin.(%)
0.30-1.00 700 600 5
1.00-2.50 700 600 10
2.50-5.00 700 600 12
5.00-20.00 650 600 10
20.00-50.00 550 470 5

Appearance: The material will be of uniform quality, free from foreign mater, splits and fractures. Bed sheet (not trimmed) may have small edge cracks.
Surface defedts are assessed in the frame of visual inspection.
Surface condition: pickled.