We believe in: Innovation is our soul and spirit. Excellent is our life. Shopper need to have is our God for Factory Supply Electric Heating Plate For University Laboratory, We goal at Ongoing system innovation, management innovation, elite innovation and sector innovation, give full play for the overall advantages, and constantly make improvements to support excellent.
We believe in: Innovation is our soul and spirit. Excellent is our life. Shopper need to have is our God for Electric Heating Plate For Laboratory University Inspection Department, Electric Heating Plate For University Laboratory, We integrate all our advantages to continuously innovate, improve and optimize our industrial structure and product performance. We are going to always believe in and work on it. Welcome to join us to promote green light, together we’ll make a better Future!
Chemical composition:

Main and minor components Min.content(%) ASTM B386 (361)
Mo Balance balance
Ti 0.40-0.55% 0.40-0.55%
Zr 0.06-0.12% 0.06-0.12%
Impurities Max.values (μg/g) Max.values (μg/g)
Al 10 -
Cu 20 -
Cr 20 -
Fe 20 100
K 20 -
Ni 10 50
Si 20 100
W 300 -
C 100-400 100-400-
H 10 -
N 10 20
O 500 300
Cd 5 -
Hg 1 -
Pb 5 -

Dimensions and tolerances:

Cold rolled sheets
Thickness(mm) Thickness tolerace(±mm) Maximal width(mm) Width tolerace(±mm)
0.30-0.50 0.028 300 1.0
Hot rolled sheets
Thickness(mm) Thickness tolerace(±mm) Maximal width(mm) Width tolerace(±mm)
0.50-0.60 0.06 850 1.6
0.60-1.00 0.08 850 1.6
1.00-1.50 0.13 850 2.0
1.50-2.00 0.15 850 2.0
2.00-3.60 0.18 850 2.0
3.60-50.0 5% 1000 2.0

Length tolerance:
The length tolerance for all dimension is maximal +5/-0 mm.
Flatness: max. 4 % (measuring procedure on the basis of ASTM B 386)
Density: ≥ 10.1 g/cm³
Vickers Hardness: 220-320 HV
Tensile Test:

Thickness (mm) Tensile StrengthMin. (MPa) 0.2% Yield strengtMin.(MPa) ElongationMin.(%)
0.30-1.00 700 600 5
1.00-2.50 700 600 10
2.50-5.00 700 600 12
5.00-20.00 650 600 10
20.00-50.00 550 470 5

Appearance: The material will be of uniform quality, free from foreign mater, splits and fractures. Bed sheet (not trimmed) may have small edge cracks.
Surface defedts are assessed in the frame of visual inspection.
Surface condition: pickled.